Datasheet
Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more.
Note:
The Olarm LINK will require an Olarm PRO communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.

Features
DIN Rail mountable (plastic DIN rail included)
6x Protected general purpose IO Ports which can either be used as inputs or open drain outputs.
Analog sensor port for use with either 4-20mA or 0-14V sensors.
2 high current relays allow for control of AC loads or high current DC loads.
2 tamper switches.
RGB status indication light.
Olarm One-Wire Serial comms bus interface to supported Olarm communicators allowing for up to 8 Olarm LINK to be connected to one communicator.
Alarm panels compatible with Olarm PRO
Paradox
Texecom
IDS
MG5050
Premier 412
806
MG5050+
Premier 816
X16
SP6000
Premier 816 PLUS
X64
SP6000+
Elite 24
X64 SERIAL
SP65
Elite 48
EVO192
Elite 64
Elite 88
Elite 168
Please Note: Olarm LINK is not compatible with DSC Power Series and IDS 805 alarm panels.
Electric Fences compatible with Olarm PRO
Nemtek
JVA
Druid D13, D15, D18, D20, D25, D28
Z-Range: Z11, Z13, Z14, Z18, Z28
Merlin 4i
Merlin Stealth M18S, M28S, M28X
Please Note: Olarm LINK is not compatible with DSC Power Series and IDS 805 alarm panels.
Mechanical specifications
Packaged weight
107 g
Cable weight
40g
Device dimensions
87 mm length
70 mm width
37 mm height
Enclosure material
ABS - Resin MG47F
Mounting
DIN Rail (plastic DIN rail included)
Power supply
Input voltage
7 to 24VDC
Current consumption
25mA (typical), 250mA (max) at 12 VDC
Operating conditions
Temperature
–40 to 60°C
Humidity
0 - 90% RH
Connectivity
Via an Olarm PRO or Olarm PRO 4G communicator.
Protocol
Olarm One-Wire Serial
Max cable length
8 meter
Models
LINK8S
6 GPIO, 2 relays, 1 analog sensor
LINK8
6 GPIO, 2 relays
General purpose IO ports
Number of ports
6
Voltage tolerance
0-20 VDC
Max open drain current
120 mA
Sensor Port
Number of ports
1 configurable to voltage or current
Voltage sensor
0-15 VDC
Current sensor
4-20 mA
Smart Input
In app status view of the LED status on supported peripherals
Number of ports
1
Connect the Voltage sensor port to the status LED
Supported peripherals
Centurion D5 Evo
Centurion D5 Smart
Centurion D10 Smart
ET Nice Drive 500
Relays
Number of relays
2
Contacts per relay
1x Normally Open (NO)
1x Normally Closed (NC)
Max voltage
240 VAC / 28 VDC
Max current
10 A
Configuration
Auto-detection when connected to an Olarm communicator. Follow the instructions in the Olarm APP once connected and LED is blue.
Signal
Contact ID on certain events
Included in the box
1x Olarm LINK
1x 1.5m communications cable
1x Plastic DIN rail
1x DIN rail clip
2x screws & 2x wall plugs
Certifications, accreditations & test reports
Safety & health
EN 62368-1:2014+A11 (2017)
IEC 62368-1: (2014)
Electromagnetic compatibility
ETSI EN 301 489-1: V2.2.3 (2019-11)
ETSI EN 301 489-17: V3.2.4 (2020-09)
EN 50130-4: 2011+A1:2014