DATASHEET
Olarm LINK
Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more.
The Olarm LINK will require an Olarm communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.
DATASHEET
Olarm LINK
Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more.
The Olarm LINK will require an Olarm communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.
DATASHEET
Olarm LINK
Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more.
The Olarm LINK will require an Olarm communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.
Features
DIN Rail mountable (plastic DIN rail included)
DIN Rail mountable (plastic DIN rail included)
6x Protected general purpose IO Ports which can either be used as inputs or open drain outputs.
6x Protected general purpose IO Ports which can either be used as inputs or open drain outputs.
Analog sensor port for use with either 4-20mA or 0-14V sensors.
Analog sensor port for use with either 4-20mA or 0-14V sensors.
2 high current relays allow for control of AC loads or high current DC loads.
2 high current relays allow for control of AC loads or high current DC loads.
2 tamper switches.
2 tamper switches.
RGB status indication light.
RGB status indication light.
Olarm One-Wire Serial comms bus interface to supported Olarm communicators allowing for up to 8 Olarm LINK to be connected to one communicator.
Olarm One-Wire Serial comms bus interface to supported Olarm communicators allowing for up to 8 Olarm LINK to be connected to one communicator.
Alarm Panels compatible with Olarm LINK
Paradox
Paradox
MG5050
MG5050
MG5050+
MG5050+
SP6000
SP6000
SP6000+
SP6000+
SP65
SP65
EVO192
EVO192
Texecom
Texecom
Premier 412
Premier 412
Premier 816
Premier 816
Premier 816 PLUS
Premier 816 PLUS
Elite 24
Elite 24
Elite 48
Elite 48
Elite 64
Elite 64
Elite 88
Elite 88
Elite 168
Elite 168
IDS
IDS
806
806
X16
X16
X64
X64
X64 Serial
X64 Serial
Please Note: Olarm LINK is not compatible with DSC Power Series and IDS 805 alarm panels.
Please Note: Olarm LINK is not compatible with DSC Power Series and IDS 805 alarm panels.
Mechanical Specifications
Packaged weight
107 g
Packaged weight
107 g
Cable weight
40g
Cable weight
40g
Device dimensions
87 mm length 70 mm width 37 mm height
Device dimensions
87 mm length 70 mm width 37 mm height
Enclosure material
ABS - Resin MG47F
Enclosure material
ABS - Resin MG47F
Mounting
DIN Rail (plastic DIN rail included)
Mounting
DIN Rail (plastic DIN rail included)
Power supply
Input voltage
7 to 24 VDC
Input voltage
7 to 24 VDC
Current consumption
25mA (typical), 250mA (max) at 12 VDC
Current consumption
25mA (typical), 250mA (max) at 12 VDC
Operating conditions
Temperature
–40 to 60°C
Temperature
–40 to 60°C
Humidity
0 - 90% RH
Humidity
0 - 90% RH
Connectivity
Via an Olarm PRO, Olarm PRO 4G or Olarm MAX communicator.
Via an Olarm PRO, Olarm PRO 4G or Olarm MAX communicator.
Protocol
Olarm One-Wire Serial
Protocol
Olarm One-Wire Serial
Max cable length
8 meter
Max cable length
8 meter
Models
LINK8S
6 GPIO, 2 relays, 1 analog sensor
LINK8S
6 GPIO, 2 relays, 1 analog sensor
LINK8
6 GPIO, 2 relays
LINK8
6 GPIO, 2 relays
General Purpose IO Ports
Number of ports
6
Number of ports
6
Voltage tolerance
0-20 VDC
Voltage tolerance
0-20 VDC
Max open drain current
120 mA
Max open drain current
120 mA
Sensor Port
Number of ports
1 configurable to voltage or current
Number of ports
1 configurable to voltage or current
Voltage sensor
0-15 VDC
Voltage sensor
0-15 VDC
Current sensor
4-20 mA
Current sensor
4-20 mA
Smart Input
In app status view of the LED status on supported peripherals
In app status view of the LED status on supported peripherals
Number of ports
1 Connect the Voltage sensor port to the status LED
Number of ports
1 Connect the Voltage sensor port to the status LED
Supported peripherals
Centurion D5 Evo Centurion D5 Smart Centurion D10 Smart ET Nice Drive 500
Supported peripherals
Centurion D5 Evo Centurion D5 Smart Centurion D10 Smart ET Nice Drive 500
Please log a support request should your device not be listed. The team will investigate whether or not support for your device can be configured.
Please log a support request should your device not be listed. The team will investigate whether or not support for your device can be configured.
Relays
Number of relays
2
Number of relays
2
Contacts per relay
1x Normally Open (NO) 1x Normally Closed (NC)
Contacts per relay
1x Normally Open (NO) 1x Normally Closed (NC)
Max voltage
240 VAC / 28 VDC
Max voltage
240 VAC / 28 VDC
Max current
10 A
Max current
10 A
Configuration
Auto-detection when connected to an Olarm communicator. Follow the instructions in the Olarm APP once connected and LED is blue.
Auto-detection when connected to an Olarm communicator. Follow the instructions in the Olarm APP once connected and LED is blue.
Signals
Contact ID on certain events
Contact ID on certain events
Included in the box
1x Olarm LINK
1x Olarm LINK
1x 1.5m communications cable
1x 1.5m communications cable
1x Plastic DIN rail
1x Plastic DIN rail
1x DIN rail clip
1x DIN rail clip
2x screws & 2x wall plugs
2x screws & 2x wall plugs
Certifications, accreditations & test reports
Safety & Health
EN 62368-1:2014+A11: (2017)
EN 62368-1:2014+A11: (2017)
IEC 62368-1: (2014)
IEC 62368-1: (2014)
Electromagnetic Compatibility
ETSI EN 301 489-1: V2.2.3 (2019-11)
ETSI EN 301 489-1: V2.2.3 (2019-11)
ETSI EN 301 489-17: V3.2.4 (2020-09)
ETSI EN 301 489-17: V3.2.4 (2020-09)
EN 50130-4: 2011+A1: (2014)
EN 50130-4: 2011+A1: (2014)