DATASHEET

Olarm LINK

Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more. 

The Olarm LINK will require an Olarm communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.

DATASHEET

Olarm LINK

Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more. 

The Olarm LINK will require an Olarm communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.

DATASHEET

Olarm LINK

Olarm LINK is smart control and sensing device allowing users to control a wide range of peripherals such as gate motors, garage motors, boom gates, water pumps, and more. 

The Olarm LINK will require an Olarm communicator with an active subscription to function. Please contact your installer or speak to sales@olarm.com for more information.

Features

DIN Rail mountable (plastic DIN rail included)

DIN Rail mountable (plastic DIN rail included)

6x Protected general purpose IO Ports which can either be used as inputs or open drain outputs.

6x Protected general purpose IO Ports which can either be used as inputs or open drain outputs.

Analog sensor port for use with either 4-20mA or 0-14V sensors.

Analog sensor port for use with either 4-20mA or 0-14V sensors.

2 high current relays allow for control of AC loads or high current DC loads.

2 high current relays allow for control of AC loads or high current DC loads.

2 tamper switches.

2 tamper switches.

RGB status indication light.

RGB status indication light.

Olarm One-Wire Serial comms bus interface to supported Olarm communicators allowing for up to 8 Olarm LINK to be connected to one communicator.

Olarm One-Wire Serial comms bus interface to supported Olarm communicators allowing for up to 8 Olarm LINK to be connected to one communicator.

Alarm Panels compatible with Olarm LINK

Paradox

Paradox

MG5050

MG5050

MG5050+

MG5050+

SP6000

SP6000

SP6000+

SP6000+

SP65

SP65

EVO192

EVO192

Texecom

Texecom

Premier 412

Premier 412

Premier 816

Premier 816

Premier 816 PLUS

Premier 816 PLUS

Elite 24

Elite 24

Elite 48

Elite 48

Elite 64

Elite 64

Elite 88

Elite 88

Elite 168

Elite 168

IDS

IDS

806

806

X16

X16

X64

X64

X64 Serial

X64 Serial

Please Note: Olarm LINK is not compatible with DSC Power Series and IDS 805 alarm panels.

Please Note: Olarm LINK is not compatible with DSC Power Series and IDS 805 alarm panels.

Mechanical Specifications

Packaged weight

107 g

Packaged weight

107 g

Cable weight

40g

Cable weight

40g

Device dimensions

87 mm length 70 mm width 37 mm height

Device dimensions

87 mm length 70 mm width 37 mm height

Enclosure material

ABS - Resin MG47F

Enclosure material

ABS - Resin MG47F

Mounting

DIN Rail (plastic DIN rail included)

Mounting

DIN Rail (plastic DIN rail included)

Power supply

Input voltage

7 to 24 VDC

Input voltage

7 to 24 VDC

Current consumption

25mA (typical), 250mA (max) at 12 VDC

Current consumption

25mA (typical), 250mA (max) at 12 VDC

Operating conditions

Temperature

–40 to 60°C

Temperature

–40 to 60°C

Humidity

0 - 90% RH

Humidity

0 - 90% RH

Connectivity

Via an Olarm PRO, Olarm PRO 4G or Olarm MAX communicator.

Via an Olarm PRO, Olarm PRO 4G or Olarm MAX communicator.

Protocol

Olarm One-Wire Serial

Protocol

Olarm One-Wire Serial

Max cable length

8 meter

Max cable length

8 meter

Models

LINK8S

6 GPIO, 2 relays, 1 analog sensor

LINK8S

6 GPIO, 2 relays, 1 analog sensor

LINK8

6 GPIO, 2 relays

LINK8

6 GPIO, 2 relays

General Purpose IO Ports 

Number of ports

6

Number of ports

6

Voltage tolerance

0-20 VDC

Voltage tolerance

0-20 VDC

Max open drain current

120 mA

Max open drain current

120 mA

Sensor Port

Number of ports

1 configurable to voltage or current

Number of ports

1 configurable to voltage or current

Voltage sensor

0-15 VDC

Voltage sensor

0-15 VDC

Current sensor

4-20 mA

Current sensor

4-20 mA

Smart Input

In app status view of the LED status on supported peripherals

In app status view of the LED status on supported peripherals

Number of ports

1 Connect the Voltage sensor port to the status LED

Number of ports

1 Connect the Voltage sensor port to the status LED

Supported peripherals

Centurion D5 Evo Centurion D5 Smart Centurion D10 Smart ET Nice Drive 500

Supported peripherals

Centurion D5 Evo Centurion D5 Smart Centurion D10 Smart ET Nice Drive 500

Please log a support request should your device not be listed. The team will investigate whether or not support for your device can be configured.

Please log a support request should your device not be listed. The team will investigate whether or not support for your device can be configured.

Relays

Number of relays

2

Number of relays

2

Contacts per relay

1x Normally Open (NO) 1x Normally Closed (NC)

Contacts per relay

1x Normally Open (NO) 1x Normally Closed (NC)

Max voltage

240 VAC / 28 VDC

Max voltage

240 VAC / 28 VDC

Max current

10 A

Max current

10 A

Configuration

Auto-detection when connected to an Olarm communicator. Follow the instructions in the Olarm APP once connected and LED is blue.

Auto-detection when connected to an Olarm communicator. Follow the instructions in the Olarm APP once connected and LED is blue.

Signals

Contact ID on certain events

Contact ID on certain events

Included in the box

1x Olarm LINK

1x Olarm LINK

1x 1.5m communications cable

1x 1.5m communications cable

1x Plastic DIN rail

1x Plastic DIN rail

1x DIN rail clip

1x DIN rail clip

2x screws & 2x wall plugs

2x screws & 2x wall plugs

Certifications, accreditations & test reports

Safety & Health

EN 62368-1:2014+A11: (2017)

EN 62368-1:2014+A11: (2017)

IEC 62368-1: (2014)

IEC 62368-1: (2014)

Electromagnetic Compatibility

ETSI EN 301 489-1: V2.2.3 (2019-11)

ETSI EN 301 489-1: V2.2.3 (2019-11)

ETSI EN 301 489-17: V3.2.4 (2020-09)

ETSI EN 301 489-17: V3.2.4 (2020-09)

EN 50130-4: 2011+A1: (2014)

EN 50130-4: 2011+A1: (2014)

Upgrade Your Security

Olarm PRO 4G Alarm Communicator
Olarm PRO 4G Alarm Communicator

Customers

Buy Olarm

Partners

Sell Olarm